Maretron's DCR100 contains 6 Direct Current (DC) relays, each capable of switching up to 10 amps. The DCR100 connects directly to an NMEA 2000® network and the associated loads can be switched while onboard using Maretron’s dedicated NMEA 2000® displays (DSM250 or DSM410) or Maretron’s N2KView® or N2KView Mobile software.
Loads can also be switched remotely using Maretron’s Real Time Cloud Service. The DCR100 easily handles resistive DC loads like lights, or inductive DC loads like pumps and motors. The DCR100 can also be used to switch AC circuits using external relays. An added benefit of the DCR100 is that it reports the current through each of the six channels. This allows you to determine if loads are drawing too little electrical current such as burnt out bulbs, or if the loads are starting to draw too much electrical current.
* DCR100 requires configuration if two or more DCR100s, RIM100s, or SIM100s exist on single network (Maretron DSM250, DSM410, USB100, or IPG100 needed to configure)
- Six Relays for On / Off Control Over NMEA 2000® Network
- Each Relay Capable of Carrying Up to 10 amps
- Individual Relay Electrical Current Monitoring
- Automatic Relay Over Current Shutdown (Shuts Down at ≈ 12 amps)
- Automatic Relay Thermal Shutdown (Over Temperature Protection)
- Relays Switchable Using Maretron DSM150, DSM250, N2KView®, or N2KView® Mobile DCR100 Can be Configured to Activate a Buzzer, Horn, or Strobe Light as a Result of an Alert”
- Individual DCR100 Channels Can be Locked into On/Off State
- Individual DCR100 Channels Can be Configured with Default Power Up State (e.g., On/Off/Previous)
Applications:
- Remote control of navigation lights
- Remote control of boarding lights
- Burnt out bulb alerts
- Connect external lights and horns for alerts.
Electrical:
- Maximum DC Switching Current: 10A (Maximum Current Per Channel)
- DC Switching Voltage: <32 VDC
- Contact Resistance: <10 mΩ
- Current Sense Accuracy: ±100 mA
- Operating Voltage: 9 to 32 Volts (DC Voltage)
- Power Consumption: 150 mA (NMEA 2000® Interface)
- Load Equivalence Number (LEN) 3 (NMEA 2000® Spec. [1LEN = 50 mA])
- Reverse Battery Protection: Yes (Indefinitely)
- Load Dump Protection: Yes (Energy Rated per SAE J1113)
- Brand: MaretronExterior Color: BlackConnector: NMEA2000® MicroExterior Color: BlackComm Method: NMEA 2000®Country of Origin: USA
Displayed prices are inclusive of all applicable tariff and duty.